Dual purifier column design allows 24/7 operation |
Closed loop recirculation |
Piping and fittings |
304 stainless steel |
Circulation piping |
80 mm diameter with DN 80 ISO-KF flanges for easy connection to customer enclosure |
External dimensions |
48" (1219 mm) Wide x 50" (1270 mm) Deep x 62" (1575 mm) High |
External surfaces |
RAL 7035 |
Internal Features |
Internal cooling fans |
Interior LED for maintenance |
Purity Level |
< 1ppm O2 and < 1ppm H2O Purity Level |
O2 capacity = |
217 L per purifier column |
H2O capacity = |
9000 g per purifier column |
Column Valves |
Automated purifier column valves |
Interlocked with the blower. Blower will not run if the valves fail to open |
Circulation Blower |
Variable speed circulation blower |
0 to 100% |
Max flow rate = |
185 cfm (315 m3/h) |
PLC Control |
6" color touch screen |
|
Trending screen |
Pressure, O2 and H2O value is logged for 24 hours |
Pressure Control |
Automatic pressure control |
(+/- 15 mbar) |
Manual pressure control |
Footswitch |
Regeneration Sequence |
Automatic blower restart after regeneration |
Purge |
Purge valve |
O2 level, timer or manually controlled |
Vacuum |
Vacuum pump |
22 cfm (38 m3/h) rotary vane pump with oil mist eliminator & oil return kit |
Eco Mode Features |
Vacuum pump timer |
Energy reduction shuts pump off |
Automated blower speed control |
O2 level adjusts blower speed |
Component Cycle Data |
Component cycle data |
Vacuum pump, column usage, blower usage |
System Gas Requirements |
Working gas |
³ 99.995% N2 |
Working gas pressure |
55 psi (3.8 bar) |
working gas flow rate |
250 l/min |
Regeneration gas |
3-7% H2, balance N2 |
Regeneration gas pressure |
5-7 psi (0.3-0.5 bar) |
Regeneration gas flow rate |
30 l/min |